Office Air Quality: What CO₂ Measurement Tells You

White rectangular ventilation ducts with curved sections run along the ceiling of a technical space.

Office air gets worse gradually and quietly. Headaches after lunch, a meeting that loses energy in a closed room, and nobody can say why. CO₂ measurement puts a number on that feeling.

Carbon dioxide itself is not the main villain. It is, however, a reliable indicator of how many people are in a room and how well it is ventilated. The more people and the less fresh air, the faster the value climbs. Outdoors it is typically around 400 to 450 ppm; in a well-ventilated office it is somewhat higher, and in a closed meeting room it can reach well into the thousands during a long meeting.

That is why CO₂ is one of the first things worth tracking, part of what to monitor in a building before users notice a problem. It also feeds into smart heating and cooling, because ventilation and energy use are closely linked.

What CO₂ actually tells you

A CO₂ sensor does not measure “air cleanliness” in general. It will not detect dust, odours or compounds released by furniture. It mainly shows how well the air is being exchanged relative to the number of people present, which is exactly what tends to fall short in offices.

  • The value rises with occupancy. Eight people in a small room can lift CO₂ noticeably within tens of minutes.
  • The value falls with ventilation. An open window, a working heat-recovery unit or HVAC brings it back down.
  • The pattern matters more than one number. You can see when and where air quality drops and react.

Which values to watch

There is no single binding threshold for offices, and sources differ. A common practical target is around 1,000 ppm. ASHRAE 62.1 is based on keeping indoor CO₂ no more than roughly 700 ppm above the outdoor level, which works out to about 1,000 to 1,200 ppm in practice. Recent studies also suggest that much higher levels can reduce concentration, although results vary across the literature, so treat these figures as guidance rather than a medical limit.

Indicative range (ppm)What it usually meansWhat to do
up to about 800Air is exchanged wellNothing, keep watching the trend
about 800 to 1,000Normal operation, a closed-room feel beginsConsider regular airing or higher HVAC output
about 1,000 to 1,500Ventilation does not match occupancyAir the room, adjust operation, find the cause
above about 1,500Persistently insufficient air exchangeFix it systematically: HVAC, occupancy, scheduling

Rule of thumb: Do not chase a single number. Watch how often and for how long the value exceeds the threshold you chose, and in which rooms.

Where to place the sensors

Placement decides whether the data is useful. A sensor belongs in the breathing zone, roughly at seated head height, not in a corner under the ceiling and not next to a window or an air supply.

  • Meeting rooms – the fastest rise and the best place to start.
  • Open-plan areas – one sensor per reasonable section, not per floor.
  • Small offices for one or two people – a sample is usually enough, not every room.
  • Rooms with irregular use – training room, showroom, reception.

Most current sensors use NDIR (infrared) measurement and are either battery-powered wireless units or mains-powered, so they can be added to an existing building without construction work. Sensors should be checked from time to time, because readings can drift slightly over the years.

What the data shows in practice

Once you follow the pattern across a day, the numbers start to tell a story. Typical findings:

  1. A meeting room that becomes unusable after an hour. Fix: shorter blocks with an airing break, or higher ventilation when occupied.
  2. HVAC that starts too late in the morning. At 8 a.m. the space is still stale from the day before. A schedule change is enough.
  3. An overloaded room. An office with more people than it was designed for.
  4. Needless ventilation. The opposite case: HVAC running at full power in an empty building, burning energy. CO₂ can drive it according to actual need.

The last point ties in with finding hidden energy use outside working hours. Demand-based ventilation saves energy while keeping comfort where people actually are.

Note: CO₂ is not the only comfort indicator. Temperature and humidity are worth tracking alongside it; dry or overheated air can be just as unpleasant as stale air.

Examples from different types of premises

Office. Sensors in meeting rooms and open-plan areas show which rooms are harder to ventilate and when. The result is a better schedule and better HVAC settings.

Showroom and retail unit. During events and busy periods the air changes quickly. Measurement helps switch ventilation on when it is needed instead of running it all day.

Training room and studio. A group of people in a closed space is the classic case of rapidly rising CO₂. An alert tells you when it is time for a break and some fresh air.

Branch with a reception. Doors open, air mixes and values fluctuate. A trend over several weeks shows the real picture.

Checklist: getting started with air quality monitoring

  • Choose pilot rooms – meeting rooms and the busiest open-plan areas.
  • Place sensors in the breathing zone – not by a window, not under the ceiling.
  • Set a target value – for example 1,000 ppm as an indicative threshold.
  • Collect data for at least 2 to 4 weeks – you want typical operation, not a single day.
  • Add temperature and humidity – comfort is more than one number.
  • Set alerts with a sensible threshold – so they are not sent needlessly.
  • Decide who acts – the building manager, a technician or automatic ventilation.
  • Review and adjust operation – schedule, ventilation, occupancy.
  • Monitor sensor health – an outage or drifting values must be visible.

FAQ

What CO₂ level in an office is still acceptable?

There is no single binding value. In practice, around 1,000 ppm is used as an indicative target. Values well above it usually mean ventilation is not keeping up with the number of people in the room.

Is one sensor per floor enough?

Usually not. Air behaves differently in different rooms. To begin, place sensors in the highest-risk rooms, meaning meeting rooms and the busiest areas, and expand based on results.

Does it measure other pollutants too?

No. CO₂ mainly shows air exchange relative to occupancy. Dust, volatile compounds or odours need different sensors. For most offices, CO₂ plus temperature and humidity is a good foundation.

Can sensors be added to an existing building?

Usually yes. Wireless sensors are installed without construction work. Any link to the HVAC system must be assessed for the specific equipment.

Do the sensors need calibration?

Sensors can drift slightly over time, so it is sensible to compare their readings with a reference instrument now and then or have them checked following the manufacturer’s guidance.

From sensor to real action

A number on a display does not teach anyone to ventilate. Value appears when the data reaches the person who can act on it. CO₂, temperature and humidity readings are therefore collected in one place together with other building data and shown in the INTECHI client zone. An alert goes to whoever should handle it, and in one step it becomes a service request in INTECHI Digital Management. Devices are registered, so it is clear where each sensor is and when it last reported. You can start with a few meeting rooms and later add more areas or a link to the HVAC system. More information is on the Smart technologies page at intechi.cz.

How INTECHI approaches it

INTECHI TECHNOLOGY designs air quality monitoring as part of an overall view of the building: sensors, alerts, evaluation and follow-up service in one place, in one client zone. We use the same technology as INTECHI at intechi.cz. If you want to know where it makes sense to start in your premises, get in touch.